{"id":21502,"date":"2025-04-27T05:43:07","date_gmt":"2025-04-27T05:43:07","guid":{"rendered":"https:\/\/www.suqinszconnectors.com\/?post_type=news&#038;p=21502"},"modified":"2025-04-27T06:12:34","modified_gmt":"2025-04-27T06:12:34","slug":"2025-eu-automotive-standards-update-wire-harness-connectors-must-meet-new-emc-regulations-%ef%bb%bf","status":"publish","type":"news","link":"https:\/\/www.suqinszconnectors.com\/de\/news\/2025-eu-automotive-standards-update-wire-harness-connectors-must-meet-new-emc-regulations-%ef%bb%bf\/","title":{"rendered":"Aktualisierung der EU-Automobilstandards 2025: Kabelbaumstecker m\u00fcssen neue EMV-Vorschriften erf\u00fcllen"},"content":{"rendered":"<p style=\"text-align: left;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Die aktualisierten <a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2025\/258\/oj\/eng\">EMV<\/a> (Elektromagnetische Vertr\u00e4glichkeit) Standards f\u00fcr Automobilkomponenten der Europ\u00e4ischen Union, die ab Januar 2025 in Kraft treten, bringen entscheidende \u00c4nderungen f\u00fcr Kabelbaumstecker mit sich. Nicht konforme Teile riskieren Lieferkettenverz\u00f6gerungen, Bu\u00dfgelder oder R\u00fcckrufe von Fahrzeugen. Hier ist, was Ingenieure und Beschaffungsteams wissen m\u00fcssen:<\/span><\/p>\n<h3 style=\"display: inline !important; text-align: left;\"><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200c1. Wichtige Testaktualisierungen\u200c<\/span><\/strong><\/h3>\n<ul style=\"text-align: left;\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cStrahlungsimissionen (CISPR 25 Ed.6)\u200c: Stecker m\u00fcssen jetzt Frequenzen von 30MHz\u20131GHz mit Emissionen \u226430dB\u03bcV\/m aushalten. Dies ersetzt die vorherige Obergrenze von 100MHz.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cLeitungsgebundene Immunit\u00e4t (ISO 11452-8:2025)\u200c: DC-Impedanzschwellen sinken von 50m\u03a9 auf 30m\u03a9, was verbesserte Abschirmdesigns erfordert.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cHochspannungssysteme\u200c: Stecker f\u00fcr EV-Batteriepacks (\u226560V) und Ladesteckdosen ben\u00f6tigen doppelte Zertifizierungen: E-Mark (R10) und IEC 60512-27-100.<\/span><\/li>\n<\/ul>\n<h3 style=\"display: inline !important; text-align: right;\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"450\" class=\"alignnone size-full wp-image-21509 aligncenter\" alt=\"ChamberEMC_resize\" src=\"https:\/\/www.suqinszconnectors.com\/uploads\/ChamberEMC_resize1.jpg\" srcset=\"https:\/\/www.suqinszconnectors.com\/uploads\/ChamberEMC_resize1.jpg 600w, https:\/\/www.suqinszconnectors.com\/uploads\/ChamberEMC_resize1-300x225.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/h3>\n<h3 style=\"display: inline !important; text-align: left;\"><\/h3>\n<h3 style=\"display: inline !important; text-align: left;\"><strong><span style=\"font-size: small; font-family: arial, helvetica, sans-serif;\">2. Erweiterter Geltungsbereich\u200c<\/span><\/strong><\/h3>\n<ul style=\"text-align: left;\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cAutonomes Fahrsystem\u200c: Hochgeschwindigkeits-Ethernet-Stecker (10Gbps+) m\u00fcssen EMC-Tests bis 6GHz bestehen.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cAftermarket-Teile\u200c: Nachr\u00fcst-Stecker, die im EU-Markt verkauft werden, m\u00fcssen jetzt konform sein, um fr\u00fchere regulatorische Schlupfl\u00f6cher zu schlie\u00dfen.<\/span><\/li>\n<\/ul>\n<hr \/>\n<h2 style=\"text-align: left;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">\u200cWie man konforme Kabelbaumstecker ausw\u00e4hlt\u200c<\/span><\/h2>\n<h3 style=\"text-align: left;\"><span style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"><strong>\u200c1. Technische Spezifikationen \u00fcberpr\u00fcfen\u200c<\/strong><\/span><\/h3>\n<ul style=\"text-align: left;\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cAbschirmungseffektivit\u00e4t\u200c: W\u00e4hlen Sie eine doppellagige Abschirmung (z.B. Aluminiumfolie + geflochtenes Kupfer) mit \u226585%-Abdeckung. Einlagige Designs bestehen die Schwellenwerte 2025 nicht.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cKontaktmaterialien\u200c: Goldbeschichtete Kontakte (\u22650,2\u00b5m Dicke) verringern den Widerstand auf \u22645m\u03a9, was f\u00fcr Hochstrom-EV-Anwendungen entscheidend ist.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">\u200cZertifizierungen\u200c: Fordern Sie von Lieferanten g\u00fcltige E-Mark (R10) und ISO 11452-8:2025 Testberichte an.<\/span><\/li>\n<\/ul>\n<h3 style=\"text-align: left;\"><span style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"><strong>\u200c2. F\u00e4higkeiten des Lieferanten bewerten\u200c<\/strong><\/span><\/h3>\n<ul style=\"text-align: left;\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Fordern Sie Rohdaten der EMC-Tests an (z.B. Messberichte aus schalltoten Kammern) und Dokumentation zur Fehleranalyse.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: center;\">\u00a0<a href=\"https:\/\/www.suqinszconnectors.com\/uploads\/Automotive-EMC-Testing.jpg\"><img decoding=\"async\" width=\"600\" height=\"491\" class=\"alignnone size-full wp-image-21510\" alt=\"Automobil-EMC-Pr\u00fcfung\" src=\"https:\/\/www.suqinszconnectors.com\/uploads\/Automotive-EMC-Testing.jpg\" srcset=\"https:\/\/www.suqinszconnectors.com\/uploads\/Automotive-EMC-Testing.jpg 600w, https:\/\/www.suqinszconnectors.com\/uploads\/Automotive-EMC-Testing-300x245.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<ul style=\"text-align: left;\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small; text-align: center;\">Pr\u00fcfen Sie die Herstellungsprozesse auf Einhaltung von IATF 16949:2025, insbesondere Toleranzen beim Abschirmungskragen (\u22640,1mm Abweichung).<\/span><\/li>\n<\/ul>\n<h3 style=\"text-align: center;\"><a href=\"https:\/\/www.suqinszconnectors.com\/uploads\/Microscopic-view.jpg\"><img decoding=\"async\" width=\"600\" height=\"463\" class=\"alignnone size-full wp-image-21511\" alt=\"Goldbeschichteter Terminalausschnitt\" src=\"https:\/\/www.suqinszconnectors.com\/uploads\/Microscopic-view.jpg\" srcset=\"https:\/\/www.suqinszconnectors.com\/uploads\/Microscopic-view.jpg 600w, https:\/\/www.suqinszconnectors.com\/uploads\/Microscopic-view-300x231.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/h3>\n<h3 style=\"text-align: left;\"><span style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"><strong>\u200c3. Kosten-Nutzen-Abw\u00e4gung bei Konformit\u00e4t\u200c<\/strong><\/span><\/h3>\n<ul style=\"text-align: left;\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Aluminiumkontakte k\u00f6nnen Materialkosten um 15\u201320% einsparen, erh\u00f6hen jedoch langfristig das Risiko durch h\u00f6here Oxidationsraten.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Modulare Steckersysteme reduzieren Lagerkosten um 30% und gew\u00e4hrleisten gleichzeitig Kompatibilit\u00e4t mit \u00e4lteren und neuen Fahrzeugen.<\/span><\/li>\n<\/ul>\n<hr \/>\n<h2 style=\"text-align: left;\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">\u200cEmpfohlene konforme Produkte\u200c<\/span><\/h2>\n<ol style=\"text-align: left;\">\n<li>\n<h3><strong><span style=\"font-family: arial, helvetica, sans-serif;\"><a title=\"hdscs\" href=\"https:\/\/www.suqinszconnectors.com\/de\/8-pin-male-tyco-hdscs-waterproof-automotive-electrical-connector-1-1564512-1-product\/\" target=\"_blank\"><span style=\"font-size: small;\">\u200cTE Connectivity DEUTSCH HDSC 800 Serie\u200c<\/span><\/a><\/span><\/strong><\/h3>\n<ul>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Besteht die CISPR 25 Klasse 5 Pr\u00fcfung bei 800V.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Integrierte Fl\u00fcssigkeitsk\u00fchlung f\u00fcr EV-Batteriesysteme.<\/span><\/li>\n<\/ul>\n<\/li>\n<li>\n<h3><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"><a href=\"https:\/\/www.suqinszconnectors.com\/de\/high-voltage-interconnect%ef%bc%9a-hvrc2p30fs106s-product\/\">\u00a0\u200cRosenberger HVR 320 Hochgeschwindigkeitsstecker\u200c<\/a><\/span><\/strong><\/h3>\n<ul>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">ISO 11452-8:2025 zertifiziert mit integrierten EMI-Filtern (St\u00f6rger\u00e4uschreduzierung \u226520dB bei 2\u20136GHz).<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Kompatibel mit ADAS (Fortschrittliche Fahrerassistenzsysteme)-Architekturen.<\/span><\/li>\n<\/ul>\n<\/li>\n<li>\n<h3><span style=\"font-family: arial, helvetica, sans-serif;\"><a href=\"https:\/\/www.suqinszconnectors.com\/de\/amphenol-fci-at62-16-0122-at-series-and-ahd-series-connector-product\/\"><strong><span style=\"font-size: small;\">\u200cAmphenol FCI CeeLok FAS-X\u200c<\/span><\/strong><\/a><\/span><\/h3>\n<ul>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Unterst\u00fctzt 12Gbps Daten\u00fcbertragung (ISO 13400-3 konform).<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; font-size: small;\">Korrosionsbest\u00e4ndige IP69K-Bewertung f\u00fcr raue Umgebungen.<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>The European Union\u2019s updated EMC (Electromagnetic Compatibility) standards for automotive components, effective January 2025, introduce critical changes for wire harness connectors. Non-compliant parts risk supply chain delays, fines, or vehicle recalls. Here\u2019s what engineers and procurement teams need to know: \u200c1.Key Testing Updates\u200c \u200cRadiated Emissions (CISPR 25 Ed.6)\u200c: Connectors must now withstand 30MHz\u20131GHz frequencies with emissions \u226430dB\u03bcV\/m. This replaces the previous 100MHz upper limit. \u200cConducted Immunity (ISO 11452-8:2025)\u200c: DC impedance&#8230;<\/p>","protected":false},"author":48,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"class_list":["post-21502","news","type-news","status-publish","hentry","news_catalog-connector-news"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.suqinszconnectors.com\/de\/wp-json\/wp\/v2\/news\/21502","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.suqinszconnectors.com\/de\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.suqinszconnectors.com\/de\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.suqinszconnectors.com\/de\/wp-json\/wp\/v2\/users\/48"}],"replies":[{"embeddable":true,"href":"https:\/\/www.suqinszconnectors.com\/de\/wp-json\/wp\/v2\/comments?post=21502"}],"wp:attachment":[{"href":"https:\/\/www.suqinszconnectors.com\/de\/wp-json\/wp\/v2\/media?parent=21502"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}