{"id":18599,"date":"2024-02-05T07:21:59","date_gmt":"2024-02-05T07:21:59","guid":{"rendered":"https:\/\/www.suqinszconnectors.com\/?post_type=news&#038;p=18599"},"modified":"2024-02-05T07:21:59","modified_gmt":"2024-02-05T07:21:59","slug":"causes-of-terminal-damage-and-preventive-measures","status":"publish","type":"news","link":"https:\/\/www.suqinszconnectors.com\/es\/news\/causes-of-terminal-damage-and-preventive-measures\/","title":{"rendered":"Causas de da\u00f1o en terminales y medidas preventivas"},"content":{"rendered":"<h2><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">\u00bfCu\u00e1l es la raz\u00f3n de la oxidaci\u00f3n y el ennegrecimiento de los terminales?<\/span><\/h2>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">El proceso de uso de las empresas de terminales a menudo conduce al desarrollo de varias formas de problemas, como para nosotros puede ser la oxidaci\u00f3n negra com\u00fan, si un terminal se oxida y se vuelve negro, habr\u00e1 una capa de cosas como holl\u00edn, que est\u00e1 oxidado, y la formaci\u00f3n de sustancias negras, para eliminarlo se puede usar papel de lija o lima para lijar.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Como todos sabemos, los terminales con un grado creciente de automatizaci\u00f3n industrial y requisitos de control industrial son cada vez m\u00e1s estrictos, y la cantidad de terminales aumenta gradualmente. Con el desarrollo de la industria electr\u00f3nica, el uso de terminales cada vez m\u00e1s frecuente, y m\u00e1s tipos. Los terminales facilitan la conexi\u00f3n de cables y aplicaciones, son una secci\u00f3n de sellado en la superficie de pl\u00e1stico aislante de oro, en ambos extremos tienen orificios en los que se puede insertar el cable, y hay tornillos para sujetar o aflojar, como en el caso de dos cables, a veces necesitan conectarse, otras veces necesitan desconectarse, en este momento se pueden usar los terminales para conectarlos y pueden desconectarse en cualquier momento, sin necesidad de soldarlos o retorcerlos juntos, es muy conveniente y r\u00e1pido.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<a href=\"https:\/\/www.suqinszconnectors.com\/uploads\/connecting-terminal.png\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter  wp-image-18600\" alt=\"Terminal de conexi\u00f3n\" src=\"https:\/\/www.suqinszconnectors.com\/uploads\/connecting-terminal.png\" width=\"600\" height=\"360\" srcset=\"https:\/\/www.suqinszconnectors.com\/uploads\/connecting-terminal.png 750w, https:\/\/www.suqinszconnectors.com\/uploads\/connecting-terminal-300x180.png 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">Sin embargo, a veces puede haber este tipo de aflojamiento del terminal causado por una resistencia de contacto social demasiado grande, lo que genera sobrecalentamiento; los terminales no est\u00e1n sueltos, pero debido a que el circuito por algunas razones ambientales desconocidas y sobrecorriente generan calor, como que el voltaje del sistema de suministro de energ\u00eda sea demasiado alto, o que la carga est\u00e9 en cortocircuito, lo cual tambi\u00e9n causar\u00e1 la oxidaci\u00f3n y ennegrecimiento del terminal. Por lo tanto, las causas de los problemas de oxidaci\u00f3n y ennegrecimiento de los terminales incluyen los siguientes dos puntos.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">1. el voltaje es demasiado alto. Se puede verificar desde la fuente, el voltaje secundario del transformador en la caja de distribuci\u00f3n \u2013 el voltaje de cada equipo de energ\u00eda. Los enchufes tambi\u00e9n pueden tener fijaci\u00f3n de montaje y bloqueo. La fijaci\u00f3n de montaje puede fijar m\u00e1s s\u00f3lidamente en la placa de circuito impreso, la fijaci\u00f3n de bloqueo puede instalarse despu\u00e9s de completar el bloqueo de la madre y el enchufe.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Existen varias opciones de dise\u00f1o de enchufes para coincidir con diferentes m\u00e9todos de inserci\u00f3n femenina, como horizontal, vertical o en \u00e1ngulo hacia la placa de circuito impreso. Disponibles tanto en calibres m\u00e9tricos como est\u00e1ndar.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">2. falla a tierra. Tambi\u00e9n se puede verificar desde el transformador, y luego hacia la puesta a tierra en la caja de distribuci\u00f3n. La puesta a tierra debe estar conectada a tierra, mientras que los cables de fase normales deben estar exentos de fallas a tierra. Se puede apagar con un medidor aislado o una mesa vibratoria para medir, y realizar mediciones segmentadas, intentando solo medir segmentos de cables, cables, disyuntores, interruptores y otras l\u00edneas de alimentaci\u00f3n y distribuci\u00f3n, ya que en realidad es dif\u00edcil segmentar el caso, se extraen los equipos d\u00e9biles, equipos de detecci\u00f3n, fusibles.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">La clave de la puesta a tierra es que la resistencia de puesta a tierra debe ser baja, mientras que el \u00e1rea de contacto debe ser grande. Lo primero puede garantizar que el punto de puesta a tierra tenga un potencial cercano al potencial de la tierra, con potencial cero lo m\u00e1s bajo posible, lo que puede prevenir que pienses en tormentas el\u00e9ctricas o rel\u00e1mpagos que vuelvan por la l\u00ednea de puesta a tierra, entrando en la posibilidad de un circuito de alimentaci\u00f3n.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Lo segundo puede garantizar que haya suficiente capacidad para proporcionar un canal de corriente de falla, incluyendo rayos o fallas de cortocircuito, etc. Debido a que el proceso de construcci\u00f3n real se basa en la teor\u00eda de la tecnolog\u00eda contempor\u00e1nea y los cambios tecnol\u00f3gicos, este m\u00e9todo de puesta a tierra es factible, bueno o malo, pero tambi\u00e9n depende de c\u00f3mo sea la nueva norma o est\u00e1ndar.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<a href=\"https:\/\/www.suqinszconnectors.com\/uploads\/terminal-blocks.jpg\"><img decoding=\"async\" class=\"aligncenter  wp-image-18602\" alt=\"Bloques de terminales\" src=\"https:\/\/www.suqinszconnectors.com\/uploads\/terminal-blocks.jpg\" width=\"576\" height=\"341\" srcset=\"https:\/\/www.suqinszconnectors.com\/uploads\/terminal-blocks.jpg 960w, https:\/\/www.suqinszconnectors.com\/uploads\/terminal-blocks-300x177.jpg 300w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/a><\/span><\/p>\n<h2><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Da\u00f1o por mal contacto del terminal<\/span><\/h2>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Durante la instalaci\u00f3n de los terminales, si hay una mala conexi\u00f3n, afectar\u00e1 el uso normal de las personas y ser\u00e1 f\u00e1cil que se oxide y ennegrezca.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">La correcta instalaci\u00f3n y uso de los terminales puede garantizar que la ingenier\u00eda el\u00e9ctrica evite errores en el cableado, por lo tanto, la instalaci\u00f3n de terminales es muy importante. Si en el proceso de construcci\u00f3n falta un medio t\u00e9cnico adecuado, el rendimiento correcto de los terminales no podr\u00e1 aprovecharse completamente. Por ello, se debe prestar atenci\u00f3n a la clasificaci\u00f3n espec\u00edfica de los terminales, ya que los diferentes tipos tienen m\u00e9todos de instalaci\u00f3n muy diferentes. Por ejemplo, el tipo enchufable debe insertarse completamente para aprovechar al m\u00e1ximo su rendimiento adecuado. Los tipos de bloques de terminales y otros tipos son m\u00e1s comunes, y la instalaci\u00f3n debe basarse en la situaci\u00f3n real para elegir el m\u00e9todo adecuado.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Al instalar, se deben seleccionar terminales de calidad calificada para evitar problemas de seguridad causados por productos no aptos. Al instalar los terminales, se debe elegir el tama\u00f1o correcto seg\u00fan la situaci\u00f3n real, y distribuir razonablemente la carga trif\u00e1sica, no solo para considerar la econom\u00eda de la electricidad, sino tambi\u00e9n para garantizar la seguridad el\u00e9ctrica. Al instalar el bloque de terminales, la superficie de contacto debe estar adecuadamente pulida y recubierta con pasta conductora, para que el contacto entre el bloque de terminales y el clip conductor sea bueno y cumpla con los requisitos de resistencia de conexi\u00f3n y rendimiento el\u00e9ctrico, reduciendo la posibilidad de generaci\u00f3n de calor. La influencia en la seguridad de la l\u00ednea relacionada con los terminales debe corregirse r\u00e1pidamente. Se debe inspeccionar peri\u00f3dicamente el cable que conduce a la l\u00ednea de distribuci\u00f3n, para reducir los factores de falla perif\u00e9ricos y los peligros naturales de las l\u00edneas de distribuci\u00f3n.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<a href=\"https:\/\/www.suqinszconnectors.com\/uploads\/connection-terminal.jpg\"><img decoding=\"async\" class=\"aligncenter  wp-image-18601\" alt=\"Terminal de conexi\u00f3n\" src=\"https:\/\/www.suqinszconnectors.com\/uploads\/connection-terminal.jpg\" width=\"350\" height=\"350\" srcset=\"https:\/\/www.suqinszconnectors.com\/uploads\/connection-terminal.jpg 500w, https:\/\/www.suqinszconnectors.com\/uploads\/connection-terminal-300x300.jpg 300w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/a><\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">Si el bloque de terminales se da\u00f1a en uso, no podr\u00e1 usarse en la producci\u00f3n real. \u00bfCu\u00e1les son las causas del da\u00f1o? Si el cable pelado del bloque de terminales es demasiado corto, el \u00e1rea de crimpado de resorte ser\u00e1 demasiado peque\u00f1a, lo que facilitar\u00e1 que se desplace claramente. Para pelar, no solo se necesita experiencia operativa, sino tambi\u00e9n contar con una herramienta de pelado especial para fijar la longitud de pelado. Los terminales tienen requisitos estrictos para el \u00e1rea de secci\u00f3n transversal del cable. Si no cumple con los requisitos, los terminales del cable no podr\u00e1n insertarse completamente en los orificios de los terminales, lo que resultar\u00e1 en una conductividad reducida y problemas ocultos.<\/span><\/p>\n<p><span style=\"font-size: medium; font-family: arial, helvetica, sans-serif;\">\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: medium;\">La longitud y el grosor del crimpado del bloque de terminales deben cumplir con los requisitos relevantes. Cuando el cable es demasiado delgado, debido a la aislaci\u00f3n entre el cable y el \u00e1rea de contacto, as\u00ed como a la larga supresi\u00f3n del cable, la conductividad del cable se deteriora, lo que provoca que los terminales se quemen.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>What is the reason for the oxidation and blackening of terminals? \u00a0 The process of using the terminal companies often leads to the development of various forms of problems, such as for us can be common oxidation black, if a terminal oxidation black outside there will be a layer of things like soot, that is oxidized, and the formation of black substances, to use sandpaper or file to grind off&#8230;.<\/p>","protected":false},"author":36,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"class_list":["post-18599","news","type-news","status-publish","hentry","news_catalog-connector-news"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.suqinszconnectors.com\/es\/wp-json\/wp\/v2\/news\/18599","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.suqinszconnectors.com\/es\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.suqinszconnectors.com\/es\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.suqinszconnectors.com\/es\/wp-json\/wp\/v2\/users\/36"}],"replies":[{"embeddable":true,"href":"https:\/\/www.suqinszconnectors.com\/es\/wp-json\/wp\/v2\/comments?post=18599"}],"wp:attachment":[{"href":"https:\/\/www.suqinszconnectors.com\/es\/wp-json\/wp\/v2\/media?parent=18599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}